Skip to main content

Weekly program

A climate can carry its own weekly program, with no rules to write. It requires at least calaos_base 4.9.0, calaos-web-app 4.3.0 and calaos_mobile 4.6.0. Heating (heat) and cooling (cool) each have their own program, because their schedules and setpoints differ.

Slots and levels

  • A slot is a time range on one day of the week, with its own temperature. Several slots can share the same temperature.
  • For one program, a week holds at most 10 different temperatures. Each temperature is a level, numbered 1 to 10.
  • A slot that crosses midnight is split in two: for example Thursday 22:30 to 24:00, then Friday 00:00 to 06:00.
  • Setpoints range from 7 to 30 °C, in 0.5 steps.

Priorities

When two slots overlap, the lowest level wins: level 1 beats level 2. The level number is the priority: in a slot’s form, move the level up or down to change it.

Default setpoint

Each program has a default setpoint, applied when no slot is active. For cooling you can choose “Cooling off outside periods”: outside the slots, the setpoint is pushed to the maximum (30 °C) and the mode stays cool.

What the program does

The program generates no rules. The device writes its own setpoint:

  • when a slot starts or ends;
  • when the mode changes;
  • when you enable or pause the program;
  • when you change a level’s setpoint;
  • when the server starts.

A setpoint set by hand holds until the next of these events.

ModeEffect of the program
heat, coolwrites the active level’s setpoint
autowrites the low setpoint from the heating program and the high one from the cooling program; the minimum gap is respected (2 °C by default)
off, dry, fan_onlywrites nothing

Pausing

A Program enabled switch exists for each climate. While paused, the last setpoint stays in place and screens show “Program paused: period (xx°)”. On resume, the current slot is applied again. The switch can also be read and driven by a rule.

Editing the program

Web app, mobile app and wall display

Open the climate, then the program edit button (Edit program on the web, Program and settings on phones). Choose the Heating or Cooling tab, then the day (Mon to Sun). A 24 h strip shows the day’s slots.

  • Add a period adds a slot: start time, end time, temperature. The time field moves in 15-minute steps; typing to the minute is still possible.
  • On desktop and on the wall display you can also drag on the strip to create a selection, in 15-minute steps. The web app has no drag.
  • An 11th different temperature is refused: “This week already uses 10 different temperatures. Choose one of them:”, with the existing temperatures to tap.
  • Copy to… copies the displayed day to other days, for the active tab only. The copy replaces the target days’ slots; a confirmation is asked if one of them already has slots. An empty source day is refused.
  • In auto mode, the “i” help explains the two programs; the hatched zone between the two setpoints is the minimum gap.

A read-only session (service or offline) cannot change anything.

Remote control screens (ESP32) only display the state, for example “Level 2 until 22:30 · 20.5°”, “Program paused…” or “Cooling off until 12:00”. They cannot edit.

The climate row shows a badge for the next change, for example “▶ 17:30”.

In Calaos Installer

Open the thermostat, then Time program of… (the weekly-program dialog). The Program checkbox (in Heating and/or the Cooling group; tick the modes your heat pump offers) enables the weekly program. Unchecking it deletes the program’s setpoints, slots and levels. The number of levels is no longer a setting: it is 10 as soon as the program is enabled.

  • The program’s IOs belong to the device and sit in the Program sub-node.
  • After adding a program to an existing device, restart the server: it creates the IOs.
  • In a rule, the selector offers for example “Living room › active program”.
  • Months set in Calaos Installer are kept when edits are made from the apps.

The MCP assistant refuses to write the program IOs.

Program or rules?

The program covers typical weeks. Keep heating rules for the rest: away mode, open window, frost protection.