<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Wago PLC :: Calaos Documentation</title><link>https://doc.calaos.fr/en/hardware/wago/index.html</link><description>Wago PLC of the type 750-841, 750-880, …</description><generator>Hugo</generator><language>en-us</language><lastBuildDate>Thu, 28 Mar 2024 14:32:10 +0000</lastBuildDate><atom:link href="https://doc.calaos.fr/en/hardware/wago/index.xml" rel="self" type="application/rss+xml"/><item><title>Codesys</title><link>https://doc.calaos.fr/en/hardware/wago/codesys/index.html</link><pubDate>Wed, 06 Mar 2024 20:02:41 +0000</pubDate><guid>https://doc.calaos.fr/en/hardware/wago/codesys/index.html</guid><description>Programming Calaos on Wago PLCs To operate a Wago PLC with Calaos, it must first be loaded with the Calaos program. There are two ways to program a PLC with Calaos:&#10;using Calaos Installer using Codesys IP Address In any case, it’s necessary to configure the PLC’s IP address beforehand. It’s advisable to refer to Wago’s documentation for setting up a static IP address. By default, a PLC is set to DHCP. To switch to a static IP address, the Wago Ethernet Settings software should be used. This software also allows for searching the PLC on the network.</description></item><item><title>Failsafe mode</title><link>https://doc.calaos.fr/en/hardware/wago/failsafe/index.html</link><pubDate>Wed, 06 Mar 2024 20:03:53 +0000</pubDate><guid>https://doc.calaos.fr/en/hardware/wago/failsafe/index.html</guid><description>Wago PLC Fallback Mode The fallback mode in Calaos is an alternative operational state activated when the Calaos server can no longer communicate with the PLC, such as during a network failure. The PLC switches to fallback mode after a certain period (30 seconds) and continues to control certain elements like lighting points and shutters using switches, although not all server mode rules can be managed. The fallback mode can only execute a few simple rules automatically generated by the Calaos Installer software during the PLC’s configuration. Inputs can be associated with specific actions such as toggle, direct, shutter, etc., with parameters defined for each action.</description></item><item><title>Input module</title><link>https://doc.calaos.fr/en/hardware/wago/input/index.html</link><pubDate>Wed, 06 Mar 2024 20:02:53 +0000</pubDate><guid>https://doc.calaos.fr/en/hardware/wago/input/index.html</guid><description>4, 8, 16 Channel Input Modules Paired with the fieldbus controller, the 4, 8, 16 channel 24V DC digital input modules allow for the connection of push buttons as well as any on/off signal inputs.&#10;Wago Modules The terminal block allows for the connection of 4, 8, or 16 dry contacts and is galvanically isolated.</description></item><item><title>Output module</title><link>https://doc.calaos.fr/en/hardware/wago/output/index.html</link><pubDate>Wed, 06 Mar 2024 20:02:58 +0000</pubDate><guid>https://doc.calaos.fr/en/hardware/wago/output/index.html</guid><description>4, 8, 16 Channel Output Modules To control electrical elements such as lighting fixtures, electric blinds/shutters, controlled sockets, etc., we use a 24V DC digital output module. This on/off output terminal allows connecting up to 8 actuators. Typically, these actuators are 24V/220V 16A power relays, capable of supporting the load of lighting fixtures and controlled sockets in a house.</description></item><item><title>DALI Dimming</title><link>https://doc.calaos.fr/en/hardware/wago/dali/index.html</link><pubDate>Wed, 06 Mar 2024 20:03:09 +0000</pubDate><guid>https://doc.calaos.fr/en/hardware/wago/dali/index.html</guid><description>DALI Interface Module One of the main advantages of home automation is lighting management. To properly implement it, the ability to adjust the intensity of light points is essential. A light dimming technology uses the DALI (Digital Addressable Lighting Interface) standard.</description></item><item><title>DMX Dimming</title><link>https://doc.calaos.fr/en/hardware/wago/dmx/index.html</link><pubDate>Wed, 06 Mar 2024 20:03:14 +0000</pubDate><guid>https://doc.calaos.fr/en/hardware/wago/dmx/index.html</guid><description>DMX Interface Module DMX 512 Among the lighting control methods, there are several well-defined standards that have been widely used for a long time. One of these standards is DMX512, commonly known as DMX (Digital Multiplexing).</description></item><item><title>Bus Extender</title><link>https://doc.calaos.fr/en/hardware/wago/750-627/index.html</link><pubDate>Thu, 28 Mar 2024 14:32:10 +0000</pubDate><guid>https://doc.calaos.fr/en/hardware/wago/750-627/index.html</guid><description>Bus Extender When an electrical panel is saturated, it can be useful to move a part of the Wago controller a bit further away. For this purpose, it is possible to extend the communication bus between Wago modules using an RJ45 network cable. However, it is important to note that this is not an Ethernet network; connecting the bus directly to an Ethernet switch is not an option.</description></item><item><title>Analog</title><link>https://doc.calaos.fr/en/hardware/wago/analog/index.html</link><pubDate>Thu, 28 Mar 2024 14:30:48 +0000</pubDate><guid>https://doc.calaos.fr/en/hardware/wago/analog/index.html</guid><description>Analog Input or Output Module Among the data that one may want to measure in a house, there are many sensors that do not provide binary outputs. These sensors are connected in various ways and return an analog value. For instance, humidity sensors, sunlight sensors, brightness sensors, etc., fall into this category. Similarly, certain equipment can be controlled analogically in the range of 0-10V, such as ventilation regulators.</description></item><item><title>Temperature Module</title><link>https://doc.calaos.fr/en/hardware/wago/pt1000/index.html</link><pubDate>Thu, 28 Mar 2024 14:30:13 +0000</pubDate><guid>https://doc.calaos.fr/en/hardware/wago/pt1000/index.html</guid><description>4-Channel Temperature Sensor Modules A home automation system must gather information about ambient temperature, whether it’s outdoor or indoor. Temperature acquisition is done through PT1000 temperature sensors. This input module accepts 4 direct connections of PT1000 temperature sensors. The connection is made with 2-wire probes.&#10;The linearization across the entire temperature range is performed by the internal electronics of the module.</description></item><item><title>KNX using Wago</title><link>https://doc.calaos.fr/en/hardware/wago/knx/index.html</link><pubDate>Thu, 28 Mar 2024 14:23:16 +0000</pubDate><guid>https://doc.calaos.fr/en/hardware/wago/knx/index.html</guid><description>KNX Installation It is possible to use the Wago controller to manage a KNX installation and act as a KNX gateway.&#10;KNX is a standardized communication protocol for smart buildings. KNX emerged from the merger of the EHS, EIB (or Instabus), and Bâtibus standards.&#10;Unlike a standard electrical installation, there is no wired connection between the control units and the power supply: for example, a switch is not directly connected to the corresponding lamp. Indeed, devices and electrical equipment are connected via the BUS, which operates at 28 V. All BUS devices can be programmed using a common tool. Thus, the KNX BUS allows for a simple and highly flexible installation. Furthermore, subsequent modifications can be made without touching the wiring.</description></item></channel></rss>